SUA40IC-V12
40W 100V 50~60Hz ANALOGU SPEED CONTROLLER
□ Specification |
MODEL |
SUA□IA-V12 |
SUA□IB-V12 |
SUA□IC-V12 |
SUA□ID-V12 |
SUA□IX-V12 |
Rated Voltage |
1ø 110V 60Hz |
1ø 220V 60Hz |
1ø 100V 50/60Hz |
1ø 200V 50/60Hz |
1ø 240V 50Hz |
Output
|
6W
|
SUA06IA-V12 |
SUA06IB-V12 |
SUA06IC-V12 |
SUA06ID-V12 |
SUA06IX-V12 |
15W
|
SUA15IA-V12 |
SUA15IB-V12 |
SUA15IC-V12 |
SUA15ID-V12 |
SUA15IX-V12 |
25W
|
SUA25IA-V12 |
SUA25IB-V12 |
SUA25IC-V12 |
SUA25ID-V12 |
SUA25IX-V12 |
40W
|
SUA40IA-V12 |
SUA40IB-V12 |
SUA40IC-V12 |
SUA40ID-V12 |
SUA40IX-V12 |
60W
|
SUA60IA-V12 |
SUA60IB-V12 |
SUA60IC-V12 |
SUA60ID-V12 |
SUA60IX-V12 |
90W
|
SUA90IA-V12 |
SUA90IB-V12 |
SUA90IC-V12 |
SUA90ID-V12 |
SUA90IX-V12 |
180W
|
SUA180IA-V12 |
SUA180IB-V12 |
SUA180IC-V12 |
SUA180ID-V12 |
– |
Operation Voltage Range
|
± 10 %(standard)
|
Speed control range
|
60Hz : 90 ~ 1700 rpm 50Hz : 90 ~ 1400 rpm
|
Speed variation
|
5%(standard)
|
Speed setting device
|
Built in external speed setting device attachable |
SLOW RUN
SLOW STOP
|
None |
Temperature limits for use
|
0 ~ 40 ℃ |
Temperature limits for storage
|
-10 ~ 60 ℃
|
Humidity limits
|
85% Maximum (non condensing)
|
|
□ Method of use |
|
(1) Operation
1) Speed Control Unit and the lead wire connector of the motor are connected and then the plug cord is connected to AC power.
2) When the [RUN/STOP] switch of the control unit is switched to [RUN], then it is turned clockwise.
3) The product is made so that it will rotate in the clockwise direction. However, at times, due to gear ratio the direction of rotation for the gearhead shaft is opposite(counter-clockwise)
(2) Speed control
1) If the [Speed Volume] switch of the analogue type speed controller is turned clockwise, number of ratation of the motor increases and if it is turned counter-clockwise, slows down.
2) It is possible to control and designate the speed of the motor between 90[rpm]~1400[rpm] at 50Hz, 90[rpm]~1700[rpm] at 60Hz.
(3) Stop
1) If the [RUN/STOP] switch of the analogue thpe speed controller is switched to [STOP], the motor stops.
2) This switch is not an on-off switch for power. When the motor needs to be stopped for a long time, a separate power source should be installed and turned off.
(4)Transfromation of rotation direction (Fig.3)
1) A case of continuous operation by uni-direction
ㆍWhen the rotating direction of the motor needs to change with opposite from the conveyer unit, such as gearhead, change the position of the connection terminal on the side of the controller such that the ④COM and ⑤CCW is connected together instead of the ④COM and ⑥CW
ㆍPower cords should always be connected to the ①AC and ②AC terminals. Make sure the unit is off when connecting.
2) A case of normal/reverse operation
ㆍInstall the power supply switch (SW1) and the switch (SW2) for changeover between normal and reverse direction as shown in Fig.2 to change the direction of rotation.
ㆍInstantaneous reverse operation is not possible. The power switch (SW1) should first be turned off. Change to swith(SW2) after the motor completely stops.
|
(5) SPEED OUT
⑦and ⑧ are jacks to connect the rpm meter.
1) Number of revolutions can be seen by connecting a digital display rpm meter (both of Digital and Analogue).
(Note) Use the spec, suitable as 2000rpm , AC 10V products. |
Switch No. |
Switch contact capacity |
SW1 |
AC 125V or 250V more than 5A |
SW2 |
AC 125V or 250V more than 5A |
|
|
|
|
□ Mounting Procedure |
|
ㆍThere are 2 types of combiantion method for the control unit.
(1) Method of combination by making a rectangular hole <Refer to Fig.4A>
1) Make rectangular holes in the combination panel.
2) Assemble the main body of the controller and the front cover so that the controller body fits in the rectangular holes of the panel. Use M4 bolts and nuts to fix.
(2) Method of combination without making a rectangular hole <Refer to Fig.4B>
1) Make the holes in the combination panel.
2) Separate the main body of the controleer and the front cover.
3) Put the controller surface in the combination panel hole and fix with M3 flat-head bolts and nuts.
4) Attach the front cover of the controller to the combination panle and fix with M4 bolts and nuts.
5)The combination panel should be less than 2mm thick. |
|
|
|
□ Dimensions |
|
SUA06IA-V12, SUA15IA-V12, SUA25IA-V12, SUA40IA-V12, SUA60IA-V12, SUA90IA-V12, SUA180IA-V12, SUA06IB-V12, SUA15IB-V12, SUA25IB-V12, SUA40IB-V12, SUA60IB-V12, SUA90IB-V12, SUA180IB-V12, SUA06IC-V12, SUA15IC-V12, SUA25IC-V12, SUA40IC-V12, SUA60IC-V12, SUA90IC-V12, SUA180IC-V12, SUA06ID-V12, SUA15ID-V12, SUA25ID-V12, SUA40ID-V12, SUA60ID-V12, SUA90ID-V12, SUA180ID-V12, SUA06IX-V12, SUA15IX-V12, SUA25IX-V12, SUA40IX-V12, SUA60IX-V12, SUA90IX-V12, SUA715IA-V12, SUA715IB-V12, SUA715IC-V12, SUA715ID-V12, SUA715IX-V12, SUA15IA-V12, SUA15IB-V12, SUA15IC-V12, SUA15ID-V12, SUA15IX-V12